SanyoCBP2876 ED series
Dead - LOPTr s/cdry joints on the Q600 a TIP111 Darlington device, C606 2.2mfd 50 volts C605 located next to TIP111 which was leaking electrolyte, T600 the line driver TX which was short circuit to all legs having cooked up and R600 10 safety resistor which feeds the line drive stage from the 28 volts rail coming from the PSU.